CERTIFICATE OF ANALYSIS
Report VHL-COA-RETA-B0015 · Rev 1.0
ProductRetatrutide · 5mg
Lot numberRETA-B0015
Testing laboratoryManufacturing laboratory
Analytical methodHPLC
Date of issue6 September 2026
SupersedesNone
← All lab results Certificate of Analysis
Batch certificate · Lot RETA-B0015

Retatrutide

5mg

All specifications met 99.56% purity (HPLC) Manufacturer COA
Purity · HPLC
99.56%
As reported on this batch certificate
Batch
RETA-B0015
Method
HPLC
How to read this report
Purity (HPLC)
Of the peptide material, how much is the exact target compound. This is the headline quality number.
Total & single impurities
The small fraction of related peptide by-products. Lower is better.
Peptide content
How much of the total powder is peptide versus the bound water and salt it is stored in. The remainder being water and salt is normal for a freeze-dried peptide, not a quality issue.
Mass spectrum
Confirms the measured molecular weight matches the target, proof the vial holds the compound named.
Residual solvents, endotoxin, water
Cleanliness checks: manufacturing solvents cleared, contamination within limits, and the powder properly dried.
Pass
Every result falls inside its listed specification.
TestSpecificationResultStatus
Appearance White powder Conforms Pass
Solubility Soluble in water Conforms Pass
Purity (HPLC) ≥98.0% 99.56% Pass
Water content (Karl Fischer) ≤8.0% 2.7% Pass
Total impurities (HPLC) ≤2.0% 0.74% Pass
Largest single impurity (HPLC) ≤1.0% 0.28% Pass
Acetonitrile residue ≤0.041% <0.041% Pass
Dichloromethane residue ≤0.060% <0.060% Pass
N,N-Dimethylformamide residue ≤0.088% <0.088% Pass
Sodium salt ≤5.0% 1.3% Pass
Lead (Pb) NMT 10 ppm 0.003 ppm Pass
Arsenic (As) NMT 2 ppm 0.056 ppm Pass
Mercury (Hg) NMT 1 ppm Not detected Pass
Cadmium (Cd) NMT 5 ppm Not detected Pass
Vanadium (V) NMT 10 ppm Not detected Pass
Cobalt (Co) NMT 10 ppm 0.005 ppm Pass
Nickel (Ni) NMT 10 ppm 0.222 ppm Pass
Peptide content (N%) ≥80.0% 93.8% Pass
Conclusion
All reported specifications met for this lot.
Data verification
Values transcribed from the batch report issued by the testing laboratory and checked against the source document by two independent reads. Original report retained on file.
Released by · Vertex Health Labs
Date of issue · 6 September 2026
Scope. This document reports analytical data for the lot identified above. Vertex Health Labs is not a testing laboratory and makes no claim of laboratory accreditation. Testing was performed by the laboratory named in the document control block.
Source: Manufacturer COA for lot RETA-B0015. Results are published exactly as reported.
For Research Use Only. Not for human consumption. Not evaluated by the FDA; not intended to diagnose, treat, cure, or prevent any disease. Must be 21+ to purchase.